Human ATP Binding Cassette Transporter C4 (ABCC4) ELISA Kit

Human ATP Binding Cassette Transporter C4 (ABCC4) ELISA Kit ABCC4 DL-ABCC4-Hu ABC-C4 MRP4 MOATB Canalicular Multispecific Organic Anion Transporter B Multidrug Resistance-Associated Protein 4 Multi-specific organic anion transporter B
0
Human ATP Binding Cassette Transporter C4 (ABCC4) ELISA Kit ABCC4 DL-ABCC4-Hu ABC-C4 MRP4 MOATB Canalicular Multispecific Organic Anion Transporter B Multidrug Resistance-Associated Protein 4 Multi-specific organic anion transporter B code image

two product lines: Traditional ELISA Kit and Ready-to-Use ELISA Kit.

Traditional ELISA Kit Ready-to-Use ELISA KIT
Product name: Human ATP Binding Cassette Transporter C4 (ABCC4) ELISA Kit
Method: Sandwich
Synonyms:

ABC-C4; MRP4; MOATB; Canalicular Multispecific Organic Anion Transporter B; Multidrug Resistance-Associated Protein 4; Multi-specific organic anion transporter B

Detection range: 0.312-20ng/mL
Target Protein: ABCC4
Size: 96T/48T
Quality guarantee period: for 12 months, 16 months
Catalog number: DL-ABCC4-Hu (traditional) (ready-to-use)
Assay length 1-4.5Hours 1-3.5Hours
Advantages:
  • Competitive price.
  • High sensitivity.
  • High stability.
  • 12 months shelf life.
  • Pre-diluted Detection Reagent A and B
  • Reduction in the number of steps when conducting the test
  • All the reagents can be stored at -20℃
  • Faster reaction compare to other brands
  • 16 months shelf life
Instruction Manual DL-ABCC4-Hu.pdf DL-ABCC4-Hu.pdf
Human ATP Binding Cassette Transporter C4 (ABCC4) ELISA Kit elisa kit elisa kits
1. Overview

Other names:ABC-C4; MRP4; MOATB; Canalicular Multispecific Organic Anion Transporter B; Multidrug Resistance-Associated Protein 4; Multi-specific organic anion transporter B

Function: May be an organic anion pump relevant to cellular detoxification.

Sequence
MLPVYQEVKP  NPLQDANLCS  RVFFWWLNPL  FKIGHKRRLE  EDDMYSVLPE  
DRSQHLGEEL  QGFWDKEVLR  AENDAQKPSL  TRAIIKCYWK  SYLVLGIFTL  
IEESAKVIQP  IFLGKIINYF  ENYDPMDSVA  LNTAYAYATV  LTFCTLILAI  
LHHLYFYHVQ  CAGMRLRVAM  CHMIYRKALR  LSNMAMGKTT  TGQIVNLLSN 
DVNKFDQVTV  FLHFLWAGPL  QAIAVTALLW  MEIGISCLAG  MAVLIILLPL 
QSCFGKLFSS  LRSKTATFTD  ARIRTMNEVI  TGIRIIKMYA  WEKSFSNLIT 
NLRKKEISKI  LRSSCLRGMN  LASFFSASKI  IVFVTFTTYV  LLGSVITASR 
VFVAVTLYGA  VRLTVTLFFP  SAIERVSEAI  VSIRRIQTFL  LLDEISQRNR  
QLPSDGKKMV  HVQDFTAFWD  KASETPTLQG  LSFTVRPGEL  LAVVGPVGAG  
KSSLLSAVLG  ELAPSHGLVS  VHGRIAYVSQ  QPWVFSGTLR  SNILFGKKYE  
KERYEKVIKA  CALKKDLQLL  EDGDLTVIGD  RGTTLSGGQK  ARVNLARAVY 
QDADIYLLDD  PLSAVDAEVS  RHLFELCICQ  ILHEKITILV  THQLQYLKAA 
SQILILKDGK  MVQKGTYTEF  LKSGIDFGSL  LKKDNEESEQ  PPVPGTPTLR  
NRTFSESSVW  SQQSSRPSLK  DGALESQDTE  NVPVTLSEEN  RSEGKVGFQA  
YKNYFRAGAH  WIVFIFLILL  NTAAQVAYVL  QDWWLSYWAN  KQSMLNVTVN  
GGGNVTEKLD  LNWYLGIYSG  LTVATVLFGI  ARSLLVFYVL  VNSSQTLHNK 
MFESILKAPV  LFFDRNPIGR  ILNRFSKDIG  HLDDLLPLTF  LDFIQTLLQV  
VGVVSVAVAV  IPWIAIPLVP  LGIIFIFLRR  YFLETSRDVK  RLESTTRSPV  
FSHLSSSLQG  LWTIRAYKAE  ERCQELFDAH  QDLHSEAWFL  FLTTSRWFAV  
RLDAICAMFV  IIVAFGSLIL  AKTLDAGQVG  LALSYALTLM  GMFQWCVRQS  
AEVENMMISV  ERVIEYTDLE  KEAPWEYQKR  PPPAWPHEGV  IIFDNVNFMY  
SPGGPLVLKH  LTALIKSQEK  VGIVGRTGAG  KSSLISALFR  LSEPEGKIWI  
DKILTTEIGL  HDLRKKMSII  PQEPVLFTGT  MRKNLDPFNE  HTDEELWNAL  
QEVQLKETIE  DLPGKMDTEL  AESGSNFSVG  QRQLVCLARA  ILRKNQILII 
DEATANVDPR  TDELIQKKIR  EKFAHCTVLT  IAHRLNTIID  SDKIMVLDSG  
RLKEYDEPYV  LLQNKESLFY  KMVQQLGKAE  AAALTETAKQ  VYFKRNYPHI  
GHTDHMVTNT  SNGQPSTLTI  FETAL
 
2. Features
 
INTENDED USE
The kit is a sandwich enzyme immunoassay for the in vitro quantitative measurement of ABCC4 in human tissue homogenates, cell lysates and other biological fluids.
 
DETECTION RANGE
0.312-20ng/mL. The standard curve concentrations used for the ELISA’s were 20ng/mL, 10ng/mL, 5ng/mL, 2.5ng/mL, 1.25ng/mL, 0.625ng/mL, 0.312ng/mL.
 
SENSITIVITY
The minimum detectable dose of ABCC4 is typically less than 0.118ng/mL.
The sensitivity of this assay, or Lower Limit of Detection (LLD) was defined as the lowest protein concentration that could be differentiated from zero. It was determined by adding two standard deviations to the mean optical density value of twenty zero standard replicates and calculating the corresponding concentration.
 
SPECIFICITY
This assay has high sensitivity and excellent specificity for detection of ABCC4.
No significant cross-reactivity or interference between ABCC4 and analogues was observed.
Note: Limited by current skills and knowledge, it is impossible to perform all possible cross-reactivity detection tests between ABCC4 and all analogues, therefore, cross reactivity may still exist.

IMPORTANT NOTES
1. Limited by the current conditions and scientific technology, it is impossible to conduct comprehensive identification and analysis tests on the raw materials provided by suppliers. As a result, it is possible there are some qualitative and/or technical risks.
2. The final experimental results will be closely related to the validity of the products, operation skills of the end users and the experimental environments. Please make sure that sufficient samples are available to obtain accurate results.
3. Kits from different batches may be a little different in detection range, sensitivity and color developing time. Please perform the experiment exactly according to the instruction manual included in your kit. Electronic ones on our website are for reference only.
4. Do not mix or substitute reagents from one kit lot to another. Use only the reagents supplied by manufacturer.
5. Protect all reagents from strong light during storage and incubation. All bottle caps of reagents should be closed tightly to prevent evaporation of liquids and contamination by microorganisms.
6. There may be a foggy substance in the wells when the plate is opened at the first time. It will not have any effect on the final assay results. Do not remove microtiter plate from the storage bag until needed.
7. Incorrect procedures during reagent preparation and loading, as well as incorrect parameter setting for the plate reader may lead to incorrect results. A microplate plate reader with a bandwidth of 10nm or less and an optical density range of 0-3 O.D. or greater at 450 ± 10nm wavelength is acceptable for use in absorbance measurement. Please read the instruction carefully and adjust the instrument prior to the experiment.
8. Even the same experimenter may get different results from two separate experiments. In order to get better reproducible results, the operation of every step in the assay should be controlled. Furthermore, a preliminary experiment before the general assay for each batch is recommended.
9. Each kit has undergone several rigorous quality control tests. However, results from end users might be inconsistent with our in-house data due to some unexpected transportation conditions or different lab equipment. Intra-assay variance among kits from different batches could arise from the above factors as well.
10. Kits from different manufacturers with the same item might produce different results, since we have not compared our products with other manufacturers.
11. The standard of the kit and immunogen used for antibody preparation are commonly recombinant proteins. Different expressed sequence, expression systems, purification methods might be used in recombinant protein preparation. Besides, there might exist differences on the screening technique of antibody and antibody pairs in our kit. Thus we can not guarantee the kit could detect recombinant protein from other companies. So, it is not recommended to use the kit for the detection of recombinant protein.
12. Validity period: 12 months.
13. The instruction manual also works with the 48T kit, but all reagents in the 48T kit are reduced by half.

You can reference link of the kit as following
https://www.dldevelop.com/uploadfile/data/DL-ABCC4-Hu.pdf

Introduction
ItemStandardTest
Description

The kit is a sandwich enzyme immunoassay for the in vitro quantitative measurement of ABCC4 in human tissue homogenates, cell lysates or other biological fluids.

Conform
IdentificationColorimetricPositive
Composition Traditional ELISA Kit Ready-to-Use ELISA KITConform
Pre-coated, ready to use 96-well strip plate 1Pre-coated, ready to use 96-well strip plate 1
Plate sealer for 96 wells 2Plate sealer for 96 wells 2
Standard 2 Standard 2
Diluents buffer 1×45mLStandard Diluent 1×20mL
Detection Reagent A 1×120μLDetection Solution A 1×12mL
Detection Reagent B 1×120μLDetection Solution B 1×12mL
TMB Substrate 1×9mLTMB Substrate 1×9mL
Stop Solution 1×6mLStop Solution 1×6mL
Wash Buffer (30 × concentrate) 1×20mLWash Buffer (30 × concentrate) 1×20mL
Instruction manual 1 Instruction manual 1

Test principle

The microtiter plate provided in this kit has been pre-coated with an antibody specific to the index. Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody preparation specific to the index. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain the index, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of the index in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Recovery

Matrices listed below were spiked with certain level of recombinant ABCC4 and the recovery rates were calculated by comparing the measured value to the expected amount of the index in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 81-93 86
EDTA plasma(n=5) 80-97 88
heparin plasma(n=5) 90-101 95

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of the index and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 82-96% 83-98% 81-99% 93-101%
EDTA plasma(n=5) 88-101% 86-95% 90-102% 80-93%
heparin plasma(n=5) 80-91% 82-90% 95-104% 79-95%

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level the index were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level the index were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Stability

The stability of ELISA kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage conditions.
Note:
To minimize unnecessary influences on the performance, operation procedures and lab conditions, especially room temperature, air humidity and incubator temperatures should be strictly regulated. It is also strongly suggested that the whole assay is performed by the same experimenter from the beginning to the end.

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 2 hours at 37℃;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37℃;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 1 hour at 37℃;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 15-25 minutes at 37℃;
8. Add 50µL Stop Solution. Read at 450nm immediately.

Order or get a Quote