Rat VGF Nerve Growth Factor Inducible (VGF) ELISA Kit

Rat VGF Nerve Growth Factor Inducible (VGF) ELISA Kit  VGF DL-VGF-Ra NERP1 NERP2 Neuro-Endocrine Specific Protein VGF Neuroendocrine Regulatory Peptide
0
Rat VGF Nerve Growth Factor Inducible (VGF) ELISA Kit  VGF DL-VGF-Ra NERP1 NERP2 Neuro-Endocrine Specific Protein VGF Neuroendocrine Regulatory Peptide code image

two product lines: Traditional ELISA Kit and Ready-to-Use ELISA Kit.

Traditional ELISA Kit Ready-to-Use ELISA KIT
Product name: Rat VGF Nerve Growth Factor Inducible (VGF) ELISA Kit
Method: Sandwich
Synonyms:

NERP1; NERP2; Neuro-Endocrine Specific Protein VGF; Neuroendocrine Regulatory Peptide

Detection range: 31.25-2000pg/mL
Target Protein: VGF
Size: 96T/48T
Quality guarantee period: for 12 months, 16 months
Catalog number: DL-VGF-Ra (traditional) (ready-to-use)
Assay length 1-4.5Hours 1-3.5Hours
Advantages:
  • Competitive price.
  • High sensitivity.
  • High stability.
  • 12 months shelf life.
  • Pre-diluted Detection Reagent A and B
  • Reduction in the number of steps when conducting the test
  • All the reagents can be stored at -20℃
  • Faster reaction compare to other brands
  • 16 months shelf life
Instruction Manual DL-VGF-Ra.pdf DL-VGF-Ra.pdf
Rat VGF Nerve Growth Factor Inducible (VGF) ELISA Kit elisa kit elisa kits
1. Overview

Other names:NERP1; NERP2; Neuro-Endocrine Specific Protein VGF; Neuroendocrine Regulatory Peptide

Function: Receptor for VEGF, VEGFB and PGF. Has a tyrosine-protein kinase activity. The VEGF-kinase ligand/receptor signaling system plays a key role in vascular development and regulation of vascular permeability. Isoform 2 and isoform 3 may have an inhibitory role in angiogenesis.

Sequence
MVSYWDTGVL  LCALLSCLLL  TGSSSGSKLK  DPELSLKGTQ  HIMQAGQTLH  
LQCRGEAAHK  WSLPEMVSKE  SERLSITKSA  CGRNGKQFCS  TLTLNTAQAN  
HTGFYSCKYL  AVPTSKKKET  ESAIYIFISD  TGRPFVEMYS  EIPEIIHMTE  
GRELVIPCRV  TSPNITVTLK  KFPLDTLIPD  GKRIIWDSRK  GFIISNATYK  
EIGLLTCEAT  VNGHLYKTNY  LTHRQTNTII  DVQISTPRPV  KLLRGHTLVL  
NCTATTPLNT  RVQMTWSYPD  EKNKRASVRR  RIDQSNSHAN  IFYSVLTIDK  
MQNKDKGLYT  CRVRSGPSFK  SVNTSVHIYD  KAFITVKHRK  QQVLETVAGK  
RSYRLSMKVK  AFPSPEVVWL  KDGLPATEKS  ARYLTRGYSL  IIKDVTEEDA  
GNYTILLSIK  QSNVFKNLTA  TLIVNVKPQI  YEKAVSSFPD  PALYPLGSRQ  
ILTCTAYGIP  QPTIKWFWHP  CNHNHSEARC  DFCSNNEESF  ILDADSNMGN  
RIESITQRMA  IIEGKNKMAS  TLVVADSRIS  GIYICIASNK  VGTVGRNISF  
YITDVPNGFH  VNLEKMPTEG  EDLKLSCTVN  KFLYRDVTWI  LLRTVNNRTM  
HYSISKQKMA  ITKEHSITLN  LTIMNVSLQD  SGTYACRARN  VYTGEEILQK  
KEITIRDQEA  PYLLRNLSDH  TVAISSSTTL  DCHANGVPEP  QITWFKNNHK  
IQQEPGIILG  PGSSTLFIER  VTEEDEGVYH  CKATNQKGSV  ESSAYLTVQG  
TSDKSNLELI  TLTCTCVAAT  LFWLLLTLFI  RKMKRSSSEI  KTDYLSIIMD  
PDEVPLDEQC  ERLPYDASKW  EFARERLKLG  KSLGRGAFGK  VVQASAFGIK  
KSPTCRTVAV  KMLKEGATAS  EYKALMTELK  ILTHIGHHLN  VVNLLGACTK  
QGGPLMVIVE  YCKYGNLSNY  LKSKRDLFFL  NKDAALHMEP  KKEKMEPGLE  
QGKKPRLDSV  TSSESFASSG  FQEDKSLSDV  EEEEDSDGFY  KEPITMEDLI  
SYSFQVARGM  EFLSSRKCIH  RDLAARNILL  SENNVVKICD  FGLARDIYKN  
PDYVRKGDTR  LPLKWMAPES  IFDKIYSTKS  DVWSYGVLLW  EIFSLGGSPY  
PGVQMDEDFC  SRLREGMRMR  APEYSTPEIY  QIMLDCWHRD  PKERPRFAEL  
VEKLGDLLQA  NVQQDGKDYI  PINAILTGNS  GFTYSTPAFS  EDFFKESISA  
PKFNSGSSDD  VRYVNAFKFM  SLERIKTFEE  LLPNATSMFD  DYQGDSSTLL  
ASPMLKRFTW  TDSKPKASLK  IDLRVTSKSK  ESGLSDVSRP  SFCHSSCGHV  
SEGKRRFTYD  HAELERKIAC  CSPPPDYNSV  VLYSTPPI

2. Features
 
INTENDED USE
The kit is a sandwich enzyme immunoassay for the in vitro quantitative measurement of VGF in human serum, plasma and other biological fluids.
 
DETECTION RANGE
78.125-5000pg/mL. The standard curve concentrations used for the ELISA’s were 5000pg/mL, 2500pg/mL, 1250pg/mL, 625pg/mL, 312pg/mL, 156pg/mL, 78.1pg/mL.
 
SENSITIVITY
The minimum detectable dose of VGF is typically less than 32pg/mL.
The sensitivity of this assay, or Lower Limit of Detection (LLD) was defined as the lowest protein concentration that could be differentiated from zero. It was determined by adding two standard deviations to the mean optical density value of twenty zero standard replicates and calculating the corresponding concentration.
 
SPECIFICITY

This assay has high sensitivity and excellent specificity for detection of VGF.
No significant cross-reactivity or interference between VGF and analogues was observed.
Note: Limited by current skills and knowledge, it is impossible to perform all possible cross-reactivity detection tests between VGF and all analogues, therefore, cross reactivity may still exist.

IMPORTANT NOTES
1. Limited by the current conditions and scientific technology, it is impossible to conduct comprehensive identification and analysis tests on the raw materials provided by suppliers. As a result, it is possible there are some qualitative and/or technical risks.
2. The final experimental results will be closely related to the validity of the products, operation skills of the end users and the experimental environments. Please make sure that sufficient samples are available to obtain accurate results.
3. Kits from different batches may be a little different in detection range, sensitivity and color developing time. Please perform the experiment exactly according to the instruction manual included in your kit. Electronic ones on our website are for reference only.
4. Do not mix or substitute reagents from one kit lot to another. Use only the reagents supplied by manufacturer.
5. Protect all reagents from strong light during storage and incubation. All bottle caps of reagents should be closed tightly to prevent evaporation of liquids and contamination by microorganisms.
6. There may be a foggy substance in the wells when the plate is opened at the first time. It will not have any effect on the final assay results. Do not remove microtiter plate from the storage bag until needed.
7. Incorrect procedures during reagent preparation and loading, as well as incorrect parameter setting for the plate reader may lead to incorrect results. A microplate plate reader with a bandwidth of 10nm or less and an optical density range of 0-3 O.D. or greater at 450 ± 10nm wavelength is acceptable for use in absorbance measurement. Please read the instruction carefully and adjust the instrument prior to the experiment.
8. Even the same experimenter may get different results from two separate experiments. In order to get better reproducible results, the operation of every step in the assay should be controlled. Furthermore, a preliminary experiment before the general assay for each batch is recommended.
9. Each kit has undergone several rigorous quality control tests. However, results from end users might be inconsistent with our in-house data due to some unexpected transportation conditions or different lab equipment. Intra-assay variance among kits from different batches could arise from the above factors as well.
10. Kits from different manufacturers with the same item might produce different results, since we have not compared our products with other manufacturers.
11. The standard of the kit and immunogen used for antibody preparation are commonly recombinant proteins. Different expressed sequence, expression systems, purification methods might be used in recombinant protein preparation. Besides, there might exist differences on the screening technique of antibody and antibody pairs in our kit. Thus we can not guarantee the kit could detect recombinant protein from other companies. So, it is not recommended to use the kit for the detection of recombinant protein.
12. Validity period: 12 months.
13. The instruction manual also works with the 48T kit, but all reagents in the 48T kit are reduced by half.
 
PRECAUTION
The Stop Solution suggested for use with this kit is an acid solution. Wear eye, hand, face, and clothing protection when using this reagent.

You can reference link of the kit as following
https://www.dldevelop.com/uploadfile/data/DL-VGF-Hu.pdf
Introduction
ItemStandardTest
Description

The kit is a sandwich enzyme immunoassay for the in vitro quantitative measurement of VGF in rat serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids.

Conform
IdentificationColorimetricPositive
Composition Traditional ELISA Kit Ready-to-Use ELISA KITConform
Pre-coated, ready to use 96-well strip plate 1Pre-coated, ready to use 96-well strip plate 1
Plate sealer for 96 wells 2Plate sealer for 96 wells 2
Standard 2 Standard 2
Diluents buffer 1×45mLStandard Diluent 1×20mL
Detection Reagent A 1×120μLDetection Solution A 1×12mL
Detection Reagent B 1×120μLDetection Solution B 1×12mL
TMB Substrate 1×9mLTMB Substrate 1×9mL
Stop Solution 1×6mLStop Solution 1×6mL
Wash Buffer (30 × concentrate) 1×20mLWash Buffer (30 × concentrate) 1×20mL
Instruction manual 1 Instruction manual 1

Test principle

The microtiter plate provided in this kit has been pre-coated with an antibody specific to the index. Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody preparation specific to the index. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain the index, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of the index in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Recovery

Matrices listed below were spiked with certain level of recombinant VGF and the recovery rates were calculated by comparing the measured value to the expected amount of the index in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 81-93 86
EDTA plasma(n=5) 80-97 88
heparin plasma(n=5) 90-101 95

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of the index and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 82-96% 83-98% 81-99% 93-101%
EDTA plasma(n=5) 88-101% 86-95% 90-102% 80-93%
heparin plasma(n=5) 80-91% 82-90% 95-104% 79-95%

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level the index were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level the index were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Stability

The stability of ELISA kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage conditions.
Note:
To minimize unnecessary influences on the performance, operation procedures and lab conditions, especially room temperature, air humidity and incubator temperatures should be strictly regulated. It is also strongly suggested that the whole assay is performed by the same experimenter from the beginning to the end.

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 2 hours at 37℃;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37℃;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 1 hour at 37℃;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 15-25 minutes at 37℃;
8. Add 50µL Stop Solution. Read at 450nm immediately.

Order or get a Quote

We will reply you within 24 hours!

Copyright @ Wuxi Donglin Sci & Tech Development Co.,Ltd. All Rights Reserved Elisa Kit|Elisa Kits Language:Chinese